Page 33

EETE JUN 2015

Passive Active Passive Active Standard Special Single-ended Differential High-voltage Current Standard Special Single-ended Differential High-voltage Current Accessories Accessories Accessories Accessories Probe Type Bandwidth Dynamic range ¸RT-ZP10, passive, single-ended 500 MHz 400 V (RMS) ¸RTM-ZP10 ¸RT-ZH10, ¸RT-ZH11 passive, single-ended 400 MHz 1 kV (RMS) ¸RT-ZZ80 passive, broadband 8 GHz 20 V (RMS) HZO30 active, single-ended 1 GHz ±8 V R&S®RT-ZS10E active, single-ended 1 GHz ±8 V R&S®RT-ZS10* active, single-ended 1 GHz ±8 V R&S®RT-ZS20* active, single-ended 1.5 GHz ±8 V R&S®RT-ZS30* active, single-ended 3 GHz ±8 V R&S®RT-ZS60* active, single-ended 6 GHz ±8 V R&S®RT-ZD01 active, differential 100 MHz ±140 V (100:1) / ±1400 V (1000:1) HZO40 active, differential 200 MHz ±20 V HZO41 active, differential 800 MHz ±15 V R&S®RT-ZD10* active, differential 1 GHz ±5 V, with R&S®RT-ZA15: ±70 V DC / ±46 V AC (peak) R&S®RT-ZD20* active, differential 1.5 GHz ±5 V, with R&S®RT-ZA15: ±70 V DC / ±46 V AC (peak) R&S®RT-ZD30* active, differential 3 GHz ±5 V, with R&S®RT-ZA15: ±70 V DC / ±46 V AC (peak) R&S®RT-ZD40* active, differential 4.5 GHz ±5 V HZO50 AC/DC, current probe 100 kHz 20 A (RMS) / ±30 A (peak) HZO51 AC/DC, current probe 20 kHz 100 A (RMS) / 1000 A (RMS) R&S®RT-ZC10 AC/DC, current probe 10 MHz 150 A (RMS) / ±300 A (peak) R&S®RT-ZC20 AC/DC, current probe 100 MHz 30 A (RMS) / ±50 A (peak) ¸RT-ZC20B R&S®HZ-15 passive, E and H near-field probes 30 MHz to 3 GHz * R&S®ProbeMeter and micro button for instrument control Multifunctional EMC near-field Fixtures Probe portfolio Probe Type Bandwidth Dynamic range ¸RT-ZP10, passive, single-ended 500 MHz 400 V (RMS) ¸RTM-ZP10 ¸RT-ZH10, ¸RT-ZH11 passive, single-ended 400 MHz 1 kV (RMS) ¸RT-ZZ80 passive, broadband 8 GHz 20 V (RMS) HZO30 active, single-ended 1 GHz ±8 V R&S®RT-ZS10E active, single-ended 1 GHz ±8 V R&S®RT-ZS10* active, single-ended 1 GHz ±8 V R&S®RT-ZS20* active, single-ended 1.5 GHz ±8 V R&S®RT-ZS30* active, single-ended 3 GHz ±8 V R&S®RT-ZS60* active, single-ended 6 GHz ±8 V R&S®RT-ZD01 active, differential 100 MHz ±140 V (100:1)/ ±1400 V (1000:1) HZO40 active, differential 200 MHz ±20 V HZO41 active, differential 800 MHz ±15 V R&S®RT-ZD10* active, differential 1 GHz ±5 V, with R&S®RT-ZA15: ±70 V DC / ±46 V AC (peak) R&S®RT-ZD20* active, differential 1.5 GHz ±5 V, with R&S®RT-ZA15: ±70 V DC / ±46 V AC (peak) R&S®RT-ZD30* active, differential 3 GHz ±5 V, with R&S®RT-ZA15: ±70 V DC / ±46 V AC (peak) R&S®RT-ZD40* active, differential 4.5 GHz ±5 V HZO50 AC/DC, current probe 100 kHz 20 A (RMS)/ ±30 A (peak) HZO51 AC/DC, current probe 20 kHz 100 A (RMS)/ 1000 A (RMS) R&S®RT-ZC10 AC/DC, current probe 10 MHz 150 A (RMS)/ ±300 A (peak) R&S®RT-ZC20 AC/DC, current probe 100 MHz 30 A (RMS)/ ±50 A (peak) ¸RT-ZC20B R&S®HZ-15 passive, E and H near-field probes 30 MHz to 3 GHz * R&S®ProbeMeter and micro button for instrument control Multifunctional EMC near-field Fixtures


EETE JUN 2015
To see the actual publication please follow the link above